BPC-157 10 mg:
Issued 2026-10-25 by HK Analytical
- Batch
- EX-BPC-2609
- Label claim
- 10 mg per vial
- Client
- Example client
- Received
- 2026-10-14
- Tested
- 2026-10-19
Result
Conforms (5 results meet the limit · 3 reported without a limit)
| Test | Result | Detail | State |
|---|---|---|---|
| Identity LC-MS | BPC-157 | [M+2H]2+ 710.36 · [M+H]+ 1419.71 · limit Matches BPC-157 | Confirmed |
| Purity HPLC-UV | 99.0 % | limit ≥ 98.0 % | Pass |
| Content HPLC, calibrated | 10.34 mg / vial | 103 % of label claim | Reported |
| Endotoxin Kinetic LAL | < 0.04 EU/mg | limit ≤ 5 EU/mg | Pass |
| Sterility USP <71>, 14 days | No growth | limit No growth | Pass |
| Residual solvents Headspace GC | Acetonitrile 120 ppm | limit ICH Q3C | Pass |
| TFA content Ion chromatography | 11.8 % of powder | Reported | |
| Water Karl Fischer | 4.2 % | Reported |
Check a PDF you were sent
sha256(file)
Turn on JavaScript to check a file here, or compare its SHA-256 with the PDF SHA-256 below.
Your browser computes the file's SHA-256 fingerprint and compares it with the one we recorded when we issued the report. The file does not leave your device. Re-saving or “printing to PDF” changes the fingerprint even when the text looks the same.
Integrity
- PDF SHA-256
- b55b1944458c72e222da5eaae378afe01cc7cab985c946e88c44d83300cebf15
- Detailed PDF SHA-256
- 36997f2638276887d0f7c6c350e801235a9af740e47bb6e2268335661567eb68
- Record SHA-256
- 65cc74ac993f46d027f8804e39a568531e1ab36f96bc14fdba6ecfe97395c203
- Signature
- Signature valid: key hk-demo-1 (demo key), fingerprint 221C 513E 8091 01F5. Checked by our server against the published keys.
- Status statements
- None: the report is as issued.
Check it yourself: download the signed record and our public keys. The SHA-256 of canonical must equal the record SHA-256, the Ed25519 signature over canonical must verify with the key named by key_id, and the signed manifest ties the PDF SHA-256 and the detailed PDF SHA-256 to the record.
This report describes only the sample tested. It does not show that other vials or batches are the same, and it is not a statement that a product is safe for use.